<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>OptiStruct Nonlinear Archives - Blog</title>
	<atom:link href="https://blog.dta.com.tr/tag/optistruct-nonlinear/feed/" rel="self" type="application/rss+xml" />
	<link>https://blog.dta.com.tr/tag/optistruct-nonlinear/</link>
	<description>DTA Mühendislik</description>
	<lastBuildDate>Tue, 21 May 2019 11:37:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://blog.dta.com.tr/wp-content/uploads/2020/11/cropped-dta_muhendislik_icon-32x32.jpg</url>
	<title>OptiStruct Nonlinear Archives - Blog</title>
	<link>https://blog.dta.com.tr/tag/optistruct-nonlinear/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fast Contact formülasyonu &#8211; Altair OptiStruct</title>
		<link>https://blog.dta.com.tr/fast-contact-formulasyonu-altair-optistruct/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 21 May 2019 11:37:16 +0000</pubDate>
				<category><![CDATA[OptiStruct]]></category>
		<category><![CDATA[Altair OptiStruct]]></category>
		<category><![CDATA[Altair OptiStruct Tips]]></category>
		<category><![CDATA[Fast Contact]]></category>
		<category><![CDATA[neuber düzeltme yöntemi]]></category>
		<category><![CDATA[OptiStruct Nonlinear]]></category>
		<category><![CDATA[temas kuvveti]]></category>
		<guid isPermaLink="false">http://blog.s-t.com.tr/?p=5864</guid>

					<description><![CDATA[<p>Altair OptiStruct  yapısal analiz ve optimizasyon yazılımında yer alan Fast Contact formülasyonu standart doğrusal olmayan temas (non-linear contact) formülasyonuna kıyasla hızlı ve benzer sonuç veren&#8230;</p>
<p>The post <a href="https://blog.dta.com.tr/fast-contact-formulasyonu-altair-optistruct/">Fast Contact formülasyonu &#8211; Altair OptiStruct</a> appeared first on <a href="https://blog.dta.com.tr">Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><a href="http://www.s-t.com.tr/altair_optistruct.html">Altair OptiStruct</a>  </strong>yapısal analiz ve optimizasyon yazılımında yer alan<strong> <span style="color: #ff0000;">Fast Contact</span></strong> formülasyonu standart doğrusal olmayan temas (non-linear contact) formülasyonuna kıyasla hızlı ve benzer sonuç veren çözüm alınmasını sağlamaktadır.</p>
<p>Ray teker arası temas kuvvetini inceleyeceğimiz aşağıdaki örnek modelde çözüm hem standart hem de Fast Contact formülasyonuyla gerçekleştirilmiştir.</p>
<p><a href="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_fast_contact_ray_teker.jpg"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-5865" src="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_fast_contact_ray_teker.jpg" alt="" width="769" height="424" /></a></p>
<p>Her iki çözümde benzer temas kuvveti değerleri elde edilirken , çözüm süresi Fast Contact formülasyonunda 8 kat daha hızlı olmaktadır.</p>
<p><a href="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_standart_fast_contact_karsilastirmasi.jpg"><img decoding="async" class="aligncenter size-full wp-image-5866" src="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_standart_fast_contact_karsilastirmasi.jpg" alt="" width="780" height="276" /></a></p>
<p><a href="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_fast_contact_cozum_suresi.jpg"><img decoding="async" class="aligncenter size-full wp-image-5867" src="https://blog.dta.com.tr/wp-content/uploads/2019/05/optistruct_fast_contact_cozum_suresi.jpg" alt="" width="782" height="168" /></a></p>
<p><em>Contact / CGAP(G) tabanlı Fast Contact :</em><br />
Modelleme yaklaşımı node to surface (N2S) ile aynıdır CONTACT kartı kullanılmaktadır. Aktif hale getirmek için PARAM, FASTCONT, YES kartı açılmalıdır.</p>
<p><em>MPC tabanlı Fast Contact modelleme</em><br />
Eski model dosyaları (input deck) için kullanışlıdır. Aktif hale getirmek için PARAM, CDITER kartı açılmalıdır.</p>
<p>&#8211; Ön gerilme (pretension) içeren modellerde kullanılabilir<br />
&#8211; <a href="http://blog.dta.com.tr/2019/05/16/neuber-duzeltme-yonteminin-analiz-ve-optimizasyonda-kullanimi-altait-optistruct/"><strong>NEUBER düzeltme yöntemiyle</strong></a> birlikte kullanılabilir<br />
&#8211; Contact Force ve Contact Pressure değerlerini yapısal optimizasyon çözümlerinde cevap fonksiyonu (response) olarak kullanabilirsiniz.<br />
&#8211; Bu yöntem non-linear malzeme, büyük yerdeğiştirme (large displacement) ve sürtünme içeren analizlerde kullanılamaz</p>
<p>Modeli, <a href="http://www.s-t.com.tr/altair_optistruct.html"><strong>Altair OptiStruct</strong></a> help içerisinde yer alan Example Guide içerisinde bulabilirisiniz.</p>
<p><a class="a2a_button_twitter" href="https://www.addtoany.com/add_to/twitter?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Ffast-contact-formulasyonu-altair-optistruct%2F&amp;linkname=Fast%20Contact%20form%C3%BClasyonu%20%E2%80%93%20Altair%20OptiStruct" title="Twitter" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_linkedin" href="https://www.addtoany.com/add_to/linkedin?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Ffast-contact-formulasyonu-altair-optistruct%2F&amp;linkname=Fast%20Contact%20form%C3%BClasyonu%20%E2%80%93%20Altair%20OptiStruct" title="LinkedIn" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_copy_link" href="https://www.addtoany.com/add_to/copy_link?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Ffast-contact-formulasyonu-altair-optistruct%2F&amp;linkname=Fast%20Contact%20form%C3%BClasyonu%20%E2%80%93%20Altair%20OptiStruct" title="Copy Link" rel="nofollow noopener" target="_blank"></a></p><p>The post <a href="https://blog.dta.com.tr/fast-contact-formulasyonu-altair-optistruct/">Fast Contact formülasyonu &#8211; Altair OptiStruct</a> appeared first on <a href="https://blog.dta.com.tr">Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Web Semineri : OptiStruct Nonlinear Simülasyon Yetenekleri</title>
		<link>https://blog.dta.com.tr/web-semineri-optistruct-nonlinear-simulasyon-yetenekleri/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 03 Feb 2017 10:12:03 +0000</pubDate>
				<category><![CDATA[HyperWorks]]></category>
		<category><![CDATA[OptiStruct]]></category>
		<category><![CDATA[HyperWorks 14.0]]></category>
		<category><![CDATA[OptiStruct Nonlinear]]></category>
		<category><![CDATA[simülasyon]]></category>
		<category><![CDATA[web semineri]]></category>
		<guid isPermaLink="false">http://blog.s-t.com.tr/?p=4851</guid>

					<description><![CDATA[<p>OptiStruct nonlinear çözüm kapasitesi, her versiyon ve güncellemede yeni özellikler ve geliştirmelerle artmaktadır. 09 Şubat perşembe günü gerçekleştireceğimiz web seminerinde OptiStruct çözücüsünü kullanarak gerçekleştirebileceğiniz nonlinear&#8230;</p>
<p>The post <a href="https://blog.dta.com.tr/web-semineri-optistruct-nonlinear-simulasyon-yetenekleri/">Web Semineri : OptiStruct Nonlinear Simülasyon Yetenekleri</a> appeared first on <a href="https://blog.dta.com.tr">Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><center></center><br />
<strong><a href="http://www.s-t.com.tr/altair_optistruct.html">OptiStruct</a></strong> nonlinear çözüm kapasitesi, her versiyon ve güncellemede yeni özellikler ve geliştirmelerle artmaktadır.<br /> 09 Şubat perşembe günü  gerçekleştireceğimiz web seminerinde <strong><a href="http://www.s-t.com.tr/altair_optistruct.html">OptiStruct </a></strong>çözücüsünü kullanarak gerçekleştirebileceğiniz nonlinear analizler, yenilikler ve ipuçları hakkında detaylı bilgiler verilecektir.</p>
<p>Aşağıdaki bağlantı adresini kullanarak web seminerine kayıt yaptırabilirsiniz.</p>
<table style="width: 60%">
<tr>
<td>&nbsp;Tarih</td>
<td>&nbsp;09 Şubat 2017</td>
</tr>
<tr>
<td>&nbsp;Saat</td>
<td>&nbsp;15:00</td>
</tr>
<tr>
<td>&nbsp;Süre</td>
<td>&nbsp;45 dakika</td>
</tr>
<tr>
<td>&nbsp;</td>
<td>&nbsp;<a href="http://www.s-t.com.tr/optistruct_nonlinear_web_semineri_2017.html">KAYIT</a></td>
</tr>
</table>
<p><a class="a2a_button_twitter" href="https://www.addtoany.com/add_to/twitter?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Fweb-semineri-optistruct-nonlinear-simulasyon-yetenekleri%2F&amp;linkname=Web%20Semineri%20%3A%20OptiStruct%20Nonlinear%20Sim%C3%BClasyon%20Yetenekleri" title="Twitter" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_linkedin" href="https://www.addtoany.com/add_to/linkedin?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Fweb-semineri-optistruct-nonlinear-simulasyon-yetenekleri%2F&amp;linkname=Web%20Semineri%20%3A%20OptiStruct%20Nonlinear%20Sim%C3%BClasyon%20Yetenekleri" title="LinkedIn" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_copy_link" href="https://www.addtoany.com/add_to/copy_link?linkurl=https%3A%2F%2Fblog.dta.com.tr%2Fweb-semineri-optistruct-nonlinear-simulasyon-yetenekleri%2F&amp;linkname=Web%20Semineri%20%3A%20OptiStruct%20Nonlinear%20Sim%C3%BClasyon%20Yetenekleri" title="Copy Link" rel="nofollow noopener" target="_blank"></a></p><p>The post <a href="https://blog.dta.com.tr/web-semineri-optistruct-nonlinear-simulasyon-yetenekleri/">Web Semineri : OptiStruct Nonlinear Simülasyon Yetenekleri</a> appeared first on <a href="https://blog.dta.com.tr">Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
